Transcript
Hello and welcome to lab. Today we're going to do experiment eleven, molar mass determination by freezing point depression. I'd like you to be my lab partner and I'd like you to follow along in your lab manual. The first step of our procedure is to make sure that the test tubes that we're going to be using are completely dry. This is really crucial because any extra water um uh that would be in here from cleaning out from a previous uh experiment, that will severely affect your freezing point uh and then the freezing point uh determination and then the molar mass. So I'm going to put a test tube in and dry this test tube out.
If you need to, use the other end of this one. You can use tweezers kind of to direct it especially in the bottom part of the test tube. Okay, now that these two are dry, we're going to continue on with our procedure. In step two, it says begin heating some tap water in a 400 ml beaker on a hot plate. And we'll replenish this water as necessary during the experiment. I'm just going to set that on low. It doesn't need to be boiling. It doesn't even need to be super hot. It's just for melting acetic acid in a test tube and you don't need much heat to do that. Then we're to assemble our apparatus.
I've already attached a test tube clamp and above it a thermometer clamp, large and small. And then I'm going to put a large 600 ml beaker on the ring stand. In steps 4 through 6 we'll do this at the balance. First we'll weigh a test tube inside a 150 ml beaker and that's just for stability. Then we will weigh about 0.5 g of our unknown and we'll record that unknown number. And then we'll transfer the unknown to the test tube and we'll re- reweigh this apparatus. Let's go to the balance room. We also need to fill this beaker with tap water to the 400 ml mark. Okay. And place it on our ring stand.
In the next step of our procedure I need to obtain about an inch, inch and a half, no more than that, of acetic acid in a clean and dry test tube. This test tube's already clean and dry. I'm going to go uh obtain that acetic acid right now. Now that I've obtained the acetic acid in our test tube, I'm going to clamp it in to the test tube clamp. It looks like I need to change the pitch a little bit. we go. So it's straight up and down. And then I'm going to lower the test tube into the water so that the acetic acid is well below the top level of the water, but not the test tube is not touching the bottom of the beaker.
Then I'll insert a 0 to 50° thermometer in 0.1 degree divisions into the test the thermometer clamp. And I'm going to clamp that so that it's in the level of the acetic acid, but definitely not touching the bottom or the side of the test tube. I'm going to position the scale so I can read it. I'm going to just change this a little bit so it's in the middle. And if I need to, I can just bring that back a little bit too. Continue to adjust the clamps as necessary to whatever is good for your setup. Don't go on what the other person that has been here before has done. Now I'm going to insert a metal stirrer in.
I probably should have done this before in a test tube. And I'm going to take this out and put the test tube in the middle. I'm going to readjust this thermometer again. And continue to adjust uh the clamps as necessary to position the equipment so that you can move this metal loop stirrer so the loop can go up and down throughout the entire volume of your acetic acid. And this is going to be really important, this stirring, so we don't get um localized cold spots uh or hot spots. Everything is the same temperature throughout the acetic acid. All right. This is all set up. And I think we're about ready to go.
We're going to insert the 0 to 100° thermometer in 1° markings into our bath. This is called our bath, the water um in the beaker. That's our bath and it's surrounding our test tube. And we are going to uh try to get the bath between 10 and 14° Celsius. Um it needs to be in that range. And we'll be adding ice, a little bit of ice every once in a while. Um and you can use uh your thermometer as a stir rod to kind of get it all the same temperature. We're going to start recording the temperature of our acetic acid. And in this experiment, this first part of the experiment, we're just determining the temperature of pure acetic acid.
And I'll explain in a minute why we have to do this step. And we'll start taking temperature readings when the acetic acid in our test tube is about 17 degrees. We'll be taking readings every 15 seconds and you can pop this. Now, one partner needs to add ice and, you know, monitor the temperature of the bath and also record the temperature reading that I will give um and monitor the time. They'll tell me what time to read the temperature. And the other partner, which is going to be me, I'll read the thermometer and I will also be stirring. Okay. Just up and down gently during the entire time that we are trying to freeze this acetic acid.
Now, a couple of things. Uh we are going to go until the acetic acid looks very slushy. Um you'll still be able to move your loop rod up and down. Um it may be a little bit more difficult. It will just look slushy or opaque. Um it will not look uh transparent like it does now. And that's how we know it has frozen. Um you'll also see your temperature very frequently, especially in the next uh two uh parts that we're going just kind of shoot up real quickly. Sometimes if your acetic acid is very pure, it won't do that. But you'll still be able to get a good freezing point. Okay. We'll uh add a little bit of ice and I'll move the stirring rod thermometer over there.
Um and we'll get the bath down to about 14. Okay. And that should be enough ice for now. Our acetic acid is a little over 20 degrees Celsius right now. And again, we're just going to wait until it's about seventeen. I'm below seventeen now, so we'll start. Here's the reading, and I will continually stir. 16.40 15 seconds. Okay, 16.32 30 seconds. 16.20 45 seconds. 15.95 And we're adding ice every once in a while. 60 seconds. 15.80 And we're starting to freeze. You can see small 75 seconds. And we are at 16.05 90 seconds. 16.20 All right, time. 16.20 All right, two minutes. 16.20 All right, time.
And 16.20 I think we've leveled out and our solution is considered frozen. Okay. Stop it. Now that we've done the first part of this experiment, we're going to remove the thermometer, stir, and test tube all as a group. And we're going to bring this to our hot water bath and it may need a little bit of stirring. We're going to dissolve all of our acetic acid so that no solid acetic acid remains. Okay. And that looks great. Then we're going to wipe this Okay, uh test tube with Oh, I see some solid acetic acid on the side. There we go. We're going to wipe this test tube completely. Uh dry it off.
We don't want any water on the outside so that when we pour the acetic acid into our test tube with our unknown solid in it, we don't want to get any water whatsoever that will really um skew our results. Now, one thing um that we should mention here that I alluded to previously is why do we need to measure the freezing point of this acetic acid. Well, uh and not take the literature value. Well, this acetic acid may not be pure. Um it may contain something else in it, maybe a little bit of water uh from previous experiments or uh just leaving the bottle open. Uh so we do need to determine that new temperature.
Additionally, um the thermometer may not be exactly uh reading the exact what we need to read for the freezing point. Um and that's okay because freezing point depression is based on delta T. So that is just fine. So we may not have the thermometer or the very fancy setup that a literature value may use um and the literature value is extremely pure acetic acid and ours may have some impurities in it. In our next step, we're going to remove the thermometer and a stir rod and just kind of touch it to the side of the test tube so that most of the acetic acid goes right back down into solution. Then we are going to pour this acetic acid into the test tube with our unknown solid.
And we're going to reweigh this apparatus together. So the solid is not completely dissolved. So I'm just going to put it in the beaker of water, warm water for a little bit, and sometimes that will help it to solve. And in the meantime, I disposed of the colder water in the ice bath here, the beaker, and I refilled that with tap water again. Stirring will help dissolve this. So, and this is in the next step, too. We need to wipe off both the stirrer. We don't want to add any extra acetic acid over and above what we've weighed. And I'll just put this in the test tube and stir it a little bit to try to get that to dissolve more quickly.
Still have a little ways to go. All right. It looks dissolved. I'm just going to leave that there for a minute. I'm also going to wipe off my thermometer that also had some acetic acid on it from our first experiment. And I'm going to insert it in the test tube. Going to set this up as before. Clamp the test tube in and then the thermometer. So, it's in the solution, but not touching the bottom. I'm going to change the pitch of this. So, the thermometer's in the center, and I'll just give this a test that I can move this up and down, and I can. All right. It is still pretty warm. And so we'll add a little bit of ice to the bath to get that acetic acid cooler.
And this time again when it's about 17 in the acetic acid in the test tube, I am going to start taking some readings. Now we know it's freezing point depression, and we've added a solute. So we would expect our freezing point to be lower than the freezing point of the pure acetic acid. Since I have a lot of time, just going to adjust this a little bit more. Perfect. Okay, we're still at we're at 22 here, so we still have a little ways to go. While I'm waiting, I'm going to go over one of my most very favorite questions that you'll see on the homework, in the error analysis, and on a very special day at the end of the semester.
Why do we use molality instead of molarity in freezing point depression experiments? And the answer is molarity changes with temperature, and molality is independent of temperature. So it's really important because we're changing temperature in this experiment that we don't use values that change with temperature such as molarity. All right, we're at uh below 17 so let's start the reading. And our initial reading is 16.50. And we'll continue to add ice every once in a while to keep that big difference in temperature. 15 seconds. Okay, I've got 16.0. Continually stirring here. 30 seconds. 15.75.
45 seconds. 15.45. 60 seconds. 15.30. 75 seconds. 15.05. 90 seconds. 14.70. All time. 14.50 All right, two minutes. 14.30 Time. 14.05 Time. 13. point oh 70 Time. 13.50 Time. 13.30 Time. 13.10 Time. 13.00 Okay, we're frozen and our temperature is rising quickly. Time. 13.80 We got a good super cooling there. Continue to read for a little while. Time. 14.55 Time. 14.80 Time. 14.95 Time. 15.00 Time. 15.00 And I think we have leveled off at our temperature. Okay. Now that this is frozen, we can remove it. I'll unclamp the thermometer first and then unclamp our test tube. And we need to warm this entire setup in our water.
Sometimes it's a little bit helpful again to do stirring. But right now I'm just going to let that um sit here because we'll need to get some new water, warmer water in our beaker in preparation for our next trial. And then we'll also need to obtain another 0.5 g of our unknown. Now that I see that our acetic acid is completely dissolved, our acetic acid and our first addition of the unknown, I'm going to continue on with step 23. Wipe the outer walls of this test tube from any water. And then I'm going to lift the thermometer and metal stir loop and just kind of give it a shake, touch it to the sides.
May even want to do it one at a time. You want to have almost all of that acetic acid gone from the test tube uh from the thermometer and the stir rod. Now we're going to take the second addition of unknown and add it to the test tube. Now you'll see some got on the walls. That's okay. We're going to gently roll this getting everything off the walls as much as possible. Kind of put that in solution. Do some more rolling. Careful not to roll acetic acid out. And just a little bit more. Okay. Now we need to get all of that dissolved before we start. We'll use our loop stirrer just to dissolve that.
If you need to put it back in the warm water, you can. But everything needs to be dissolved before you start the next freezing point depression experiment. I think that looks good. And we'll put our thermometer in also. Okay, we'll continue on with our procedure. Again, we'll insert the test tube into the bath and clamp the test tube securely. And we will clamp the thermometer in, and then we can do some adjusting. Be sure that thermometer is in the level of the acetic acid solution, but not touching the bottom. And then give the loop stirrer a test so that you know it works. Well, we are at 30 over 30 degrees, so we still have a little ways to We'll start taking data when we get below 17.
Now that we're below 17, we can start our experiment. Our initial temperature is 16.40. 15 seconds. 16.00. 30 seconds. 15 point 60. And of course here we're going to expect our temperature freezing point to be even lower than the second 45 seconds. 15.30 and that is because we've added another addition of our solute. 1 minute. 15.15 Time. 14.80 Time. point 65 Time. 14.40 Time 14.30 Time 13.95 Time 13.70 Time 13.50 Time 13.35 Time 13.10 Time 12.75 Time 12.50 We're We're cooling here. Time. 12.05 11.90 Time. 11.80 Time. 11.55 Time. 11.40 and we are freezing. You can kind of see that it's quite opaque.
Time. And 13.20 the temperature is still increasing a little bit. Time. 13.50 Time. 14.80 Excuse me, 13.80 Time. 13.80 Time. 13.80 Okay, I think that's enough. We are now done. We've got our frozen sample here. I'm going to completely take everything out. I'm going to warm up this solution and we'll need to transfer this solution to hazardous waste. In the meantime, we do need to clean up. Make sure all your equipment is clean and in the center ready for the next group. Now, you can plot all three graphs, all three runs on the same graph. Now, scale your graph appropriately. So, I think my lowest reading was in the 11s and my highest was 17.
So, you'll want to have that range for your y-axis for your temperature. And then your x-axis will be your time and you'll plot all three on the same graph and determine the freezing point of each. You can also complete the calculations and the error analysis. Thank you for being my lab partner today.